1

0 Thumbs up   0 Thumbs down

auditing


Process by which a random sample of contractor work is field reviewed for completion and data accuracy by a trained and experienced auditor.
Source: sdge.com (offline)

2

0 Thumbs up   0 Thumbs down

chemical pole brushing


Work activity within the pole brushing maintenance cycle where contractor conducts both chemical assessment and chemical application on approved SDG&E poles.  This activity normally occurs in the late fall and winter months.
Source: sdge.com (offline)

3

0 Thumbs up   0 Thumbs down

clearance


The distance measured, usually in feet, between vegetation and the nearest energized SDG&E conductor or facility.
Source: sdge.com (offline)

4

0 Thumbs up   0 Thumbs down

compliance


General term used in reference to the condition of a tree or wood pole as it relates to the applicable law, rule or regulation.  For example, a tree growing within three (3) feet of a 12kV power line would be out of compliance with California Public Resources Code (PRC), Section 4293 which requires four (4) feet clearance at all times.
Source: sdge.com (offline)

5

0 Thumbs up   0 Thumbs down

corrective maintenance program


The CMP is a maintenance program for SDG&E’s electric distribution system mandated by the California Public Utilities Commission (CPUC).
Source: sdge.com (offline)

6

0 Thumbs up   0 Thumbs down

diameter at breast height


Measurement of tree diameter, in inches, taken at 4 ½ feet above ground level. For trees growing on slopes, the measurement is taken on the uphill side of the tree.
Source: sdge.com (offline)

7

0 Thumbs up   0 Thumbs down

environmentally sensitive area


Area within the SDG&E service territory determined to be environmentally sensitive by the Environmental Services department protocols.  Work activities may be restricted or prohibited in ESAs.
Source: sdge.com (offline)

8

0 Thumbs up   0 Thumbs down

inventory tree


Tree with potential to grow into, or fall into, SDG&E primary distribution or transmission overhead electrical facilities within three (3) years from the date of inspection. Refer to SDG&E Pre-inspection Guidelines for more detailed information.
Source: sdge.com (offline)

9

0 Thumbs up   0 Thumbs down

local responsibility area


Geographic area within the SDG&E service territory where the local fire department (not state) has primary fire suppression responsibility.  Note: CPUC General Order 95, Rule 35, applies to LRAs.
Source: sdge.com (offline)

10

0 Thumbs up   0 Thumbs down

maintenance cycle


Time period between the scheduled start date of a vegetation management  activity and the next scheduled start date for the same activity.  SDG&E is currently on a one-year maintenance cycle for key program work activities (tree pruning and pole brushing).
Source: sdge.com (offline)